reF-SCAN robotic crawler clamped around a cracker tube
Home›Inspection Services›Ethylene Cracker Tube Inspection — reF-SCAN

360° cracker coil intelligence

Carburization doesn’t pick a side. Neither does our scan.

reF-SCAN is NDT Technologies’ indigenously developed robotic crawler for ethylene cracker radiant coil inspection. Its multi-channel TFET array scans the full 360° of the tube wall from the outside, and the same pass captures laser OD growth, gyroscope bowing data and HD visual evidence.

360°Full-circumference TFET coverage
Micro-damageHigh sensitivity to ID microstructural damage
25 mmPublished TFET through-wall penetration
4 layersMaterial + geometry + bowing + visual

Cracker tubes degrade from the inside, and not evenly.

Ethylene radiant coils are centrifugally cast HP-type alloys running at some of the highest metal temperatures in the plant. Their as-cast structure — an austenitic matrix with interdendritic carbide networks — changes in service: secondary carbides precipitate and coarsen, and creep cavities nucleate. Carbon from the coke layer diffuses inward, consuming chromium and leaving a depleted, magnetically altered matrix. Decoking cycles add inner-wall decarburization and micro-fissuring. Each of these begins at microstructural scale, long before bulging or cracking becomes visible.

Heat flux, coke thickness and flame proximity vary around each tube. Carburization therefore starts and grows at circumferential positions that cannot be predicted in advance — fire side, side wall or back side — and it begins at the inner wall, out of sight of visual and surface methods.

A scan that sees only part of the circumference can miss the part that fails.
  • Carburization and chromium depletion
  • Carbide precipitation and creep cavitation
  • Inner-wall decarburization and micro-fissuring
  • Creep strain and OD growth (bulging)
  • Coil bowing and sagging
  • Surface oxidation and visible damage

Four evidence streams. One tube-level decision.

Select an evidence layer to see how it contributes to the inspection decision.

01
Material

360° TFET material response

Transition Field Electromagnetic Technique (Indian Patent No. 550047) responds to microstructural change in centrifugally cast cracker tubes — carbide precipitation and coarsening, creep cavitation, carburization-driven chromium depletion and inner-wall micro-fissuring. Exciter and detector coils sit on the OD and the field passes through the full wall, giving high sensitivity to micro-damage originating at the ID. The multi-channel array covers the complete circumference, so no sector of the tube goes unread.

All four streams are captured in a single crawler pass, position-matched along the tube.

Every degree of the circumference. Every metre of the pass.

The reF-SCAN TFET probe is a multi-channel array built in two halves that close around the tube, each covering 180°. Together they read the full circumference continuously as the crawler travels the radiant pass. Wherever carburization or ID micro-damage has started — fire side, side wall or back side — it falls under a channel.

Tube cross-section with the two reF-SCAN array halves Two half-ring sensor arrays, A and B, each span 180 degrees and together surround the tube. A carburized zone starting at the inner wall sits at about the four-thirty position, directly under one sensor element. Carburized zonestarts at the inner wallArray half A180°Array half B180° Bore Tube cross-section with the two reF-SCAN array halves Two half-ring sensor arrays, A and B, each span 180 degrees and together surround the tube. A carburized zone starting at the inner wall sits at about the four-thirty position, directly under one sensor element. Array half B180°Array half A180°Carburized zonestarts at the inner wall Bore
Tube cross-section. Two array halves, each covering 180°, close around the tube — an indication at any angle sits under a channel.
Unrolled tube map: position around the tube against distance along it Illustrative map with no real data. Most of the tube reads low. One small localized patch of high deviation sits about a third of the way along. Further along, a band of moderate deviation spreads around most of the circumference. 0°90°180°270°360° Position around tube Distance along tube Localized patchCircumferential band Unrolled tube map: position around the tube against distance along it Illustrative map with no real data. Most of the tube reads low. One small localized patch of high deviation sits about a third of the way along. Further along, a band of moderate deviation spreads around most of the circumference. 0°90°180°270°360° Position around tube Distance along tube Localized patchCircumferential band
Unrolled tube map: position around the tube against distance along it. Illustrative only — no client data.

Multi-channel array, two halves

Two probe halves clamp around the tube, each covering 180°.

Continuous circumferential map

Results are plotted as an unrolled tube map: position around the tube against distance along it.

Located, not just detected

Each indication is reported with its position around the tube and its length along it.

How a partial-circumference scan compares with reF-SCAN 360°
Partial-circumference scanreF-SCAN 360°
Reads only the sectors it coversReads the full circumference
A localized carburized zone outside the scanned sector is not seenA localized zone at any angle is detected and located
No measure of how far damage has spread around the tubeCircumferential spread and axial length are both reported

From scan data to a run-to-run condition trend.

Every tube scanned receives a TFET severity grade, read together with the circumferential spread and axial length of the indication. Grading is calibrated against metallurgical examination of in-service tubes. Repeating the scan at each turnaround tracks how every tube’s condition progresses — a tube-by-tube basis for replacement planning and safe continued operation.

  • Multi-level severity grading for every tube scanned
  • Grading calibrated against destructive metallurgical examination of in-service cracker tubes
  • Early-stage microstructural damage distinguished from advanced damage, so monitoring and replacement are planned separately
  • Same grading basis reused every turnaround, so condition progression is directly comparable
360° TFET microstructural damage analysis (carburization, creep, carbide precipitation)High sensitivity to micro-damage from the IDOuter-diameter growth / bulging measurementTube bowing and sagging measurementSurface visual conditionTurnaround-to-turnaround trending and tube ranking

What a 360° cracker tube scan looks like.

Imagery from NDT Technologies inspection material, presented as an evidence-led sequence. Client names and identifiers are removed.

Inspection that changes the replacement decision.

The value is not the sensor alone — it is the coverage and usability of the evidence it produces.

01

No blind sectors

360° TFET coverage finds carburization wherever it starts around the tube, not only where a probe happened to be placed.

02

High sensitivity to ID micro-damage

Through-wall TFET picks up micro-fissuring, decarburization and carburization that begin at the inner wall, using OD access only.

03

Minimal cleaning dependency

TFET reduces dependence on highly cleaned tube surfaces, shortening preparation inside a tight turnaround window.

04

Turnaround-to-turnaround trending

Repeat scans on the same grading basis show how each tube’s condition progresses, so replacements are planned rather than forced.

Planning a furnace turnaround?

Discuss your radiant coil inspection scope with our team.