RFET testing is based on a through-transmission electromagnetic induction principle, it is used for inspection of Ferrous metal.

Basically there are two coils one Exciter & Second Detector coils. A Alternating current is applied to Exciter coil, which induces the Secondary Low powered Magnetic field in the tube wall which is received by the Detector coil
Other Services
 
Boiler Water Wall Inspection
Advance, specialized, robotic and rapid inspection technique for condition assessment of Boiler Water Wall Tubes
  • Travel 40 mtr vertically on water wall with the help of Robotic crawler
  • As it is Robotic and automated system Manual Error is eliminated
  • 5 Tubes can be scanned simultaneously
  • Minimum Cleaning is required
  • Up to 16 RFET dual frequency detector channels
  • Two frequencies are used, differentiating relevant and non-relevant signals is easy
  • 10 % wall loss can be detected
  • Equally sensitive to ID and OD defects
  • Videoscope of External surface is carried out
  • Inspects tube of 1.5” to 3.5” diameter
  • Real time Inspection can be done
Tubular Inspection ( I - Pit )
  • Boiler Drum to Drum Tubes
  • Condenser, Heat Exchangers Tube
  • Dual frequency enables to detect defect under Baffle.
  • It has absolute and Differential Channels
  • Flexible Probe can be used for Bends
Bare & Insulated Piping ( Bracelet Probe)
  • RFET for detection of corrosion under insulation
  • In-service pipes can be inspected without removal of insulation
  • Inspection of Sphere Legs
  • At 2” insulation 20% & above wall loss can be detected
  • Possible to Inspection from 4” to 36” piping
  • Test data is presented in strip chart & real time colour map